DF SERIES THERMAL CUTOFFS

Standard Dimensions • m/m
A
B
C
D
E
25.41.0
10.5
351.0
Ø1.024
4.0

Functioning Temperature (TF)
The temperature at which a thermal cutoff changes its state of conductivity to open a circuit with detection current of 10mA or less as the only load. The temperature tolerance for the UL and CSA standard is +0, -10¢XC.

Holding Temperature (TH)
The maximum temperature at which a thermal cutoff can be maintained while conducting rated current for 168 hours without functioning.

Maximum Temperature (TM)
The maximum temperature at which mechanical and electrical properties of a thermal cutoff can be maintained for 10 minutes without resuming conductivity after functioning.

Part
Number
Functioning
Temperature (C)
Tol: +0C/-4C
TH
(C)
TM
(C)

15Amp/125Vac
10Amp/250Vac

15Amp/125Vac
10Amp/250Vac

10Amp/250Vac
DF66S
66
42
130
DF72S
72
50
110
DF77S
77
55
110
DF84S
84
60
114
DF91S
91
67
121
DF98S
98
76
130
DF100S
100
78
135
DF104S
104
80
150
DF110S
110
88
140
DF119S
119
95
170
DF128S
128
106
155
DF139S
139
117
170
DF141S
141
117
171
DF152S
152
128
175
DF170S
170
146
190
DF184S
184
160
214
DF192S
192
167
210
*
DF198S
198
170
244
DF216S
216
186
241
*
DF228S
228
193
248
*
DF240S
240
200
260
*

UL/ CUL: E117626
VDE: 115369, *116219
 Approved  Pending

BACK

© 2003 Cooperator Electronic All Rights Reserved